NO | Parameters | Requirements | |||
General Requirements | |||||
1 | EV Charger Type | AC | |||
2 | Charger Capacity | 7KW | 11KW | 22KW | 44KW |
3 | Product Model NO. | ACL007A | ACL011A | ACL022A/B | ACL044B |
4 | Mounting | Ground-Mounted | |||
Input Requirements | |||||
5 | AC Supply System | Single-Phase, 3 Wire AC system |
Single-Phase, 3 Wire AC system(Type 1) Three-Phase, 5 Wire AC system(Type 2/GBT) |
||
6 | Nominal Input Voltage | AC220V±15%(Type 2/GBT) AC240V±15%(Type 1) |
AC380V±15%(Type 2/GBT) AC240V±15%(Type 1) |
||
7 | Input Frequency | 50/60±3Hz | |||
Environmental Requirements | |||||
8 | Ambient Temperature Range | -25 to 55°C | |||
9 | Ambient Humidity | 5 to 95% | |||
10 | Storage Temperature | -40 to 70°C | |||
Mechanical Requirements | |||||
11 | IP Ratings | IP 54 | |||
12 | Cooling | Natural Cooling | Air-cooled | ||
Output Requirements | |||||
13 | Number of Outputs | 1 | 1 or 2 | 2 | |
14 | Type of Each Output | AC220V±15%(Type 2/GBT) AC240V±15%(Type 1) |
AC380V±15%(Type 2/GBT) AC240V±15%(Type 1) |
||
15 | Single Output Max. Current | 32 Amp | 16 Amp (Type 2/GBT) 50 Amp (Type 1) |
16/32 Amp (Type 2/GBT) 50/80 Amp (Type 1) |
32 Amp (Type 2/GBT) 80 Amp (Type 1) |
User Interface & Display Requirements | |||||
16 | Display & Touch-Screen Size | 4.3 Inches Touch Screen | |||
17 | User Authentication | Mobile Application or User Interface / QR Code/RFID Card /Password Login | |||
18 | Metering Information | Consumption Units | |||
Communication Requirements | |||||
19 | Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |||
20 | Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |||
Protection & Safety Requirements | |||||
21 | Executive Standard | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. | |||
22 | Safety Parameters | Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |