Customization: | Available |
---|---|
Connector Type: | CCS1, CCS2, CHAdeMO, GB/T |
Installation: | Floor Type |
Still deciding? Get samples of US$ 48000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name | DC 480KW Eight Guns CCS2 EV Charging Station |
Applicable | They are suitable for occasions such as city special charging stations that provide charging for bus, taxi, public service vehicles, sanitation vehicles,logistics vehicles, etc.; city public charging stations that provide charging for private cars, commuter, bus; intercity highway charging stations and other occasions that need special DC fast charging. |
Connector | IEC 61851
IEC 62196
|
Pakage | Wooden Stake + Cardboard Shell |
NO. | Parameters | Requirements | |
General Requirements | |||
1 | EV Charger Type | DC | |
2 | Charger Capacity | 480KW | |
3 | Product Model NO. | ENC-DCF480H | |
4 | Mounting | Ground-Mounted ( Sequential ) | |
Input Requirements | |||
5 | AC Supply System | Three-Phase, 5 Wire AC system | |
6 | Nominal Input Voltage | AC380V±15% | |
7 | Input Frequency | 45-65Hz | |
8 | Cable length | 5m | |
Environmental Requirements | |||
9 | Ambient Temperature Range | -25 to 55°C | |
10 | Ambient Humidity | 5 to 95% | |
11 | Storage Temperature | -40 to 70°C | |
Electrical indicators | |||
12 | Current Limit Protection Value | ≥110% | |
13 | Steady pressure precision | ≤±0.5% | |
14 | Steady flow accuracy | ≤±1% | |
15 | Power Factor | ≥0.99(50% load above) | |
Mechanical Requirements | |||
16 | IP Ratings | IP 54 | |
17 | Cooling | Air-cooled | |
Output Requirements | |||
18 | Connector Terminal | 4 | |
19 | Number of Outputs | 8 | |
20 | Type of Each Output | DC200-750V | |
21 | Single Output Max. Current | 200 Amp | |
User Interface & Display Requirements | |||
18 | Display & Touch-Screen Size | 7 Inches Touch Screen with Shell | |
19 | User Authentication | QR Code / RFID Card / Password Login | |
20 | Metering Information | Consumption Units | |
Communication Requirements | |||
21 | Communication between EVSE and Central server | OCPP 1.6J Protocol (Optional) | |
22 | Interface between Charger and CMS | Ethernet/3G/4G/WIFI (Optional) | |
Protection & Safety Requirements | |||
23 | Executive Standard | IEC 62196 2017, IEC 61851 2017 | |
24 | Safety Parameters | Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |