Customization: | Available |
---|---|
Charge Method: | Quick Charge |
Installation: | Portable |
Still deciding? Get samples of US$ 3800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
S. NO. | Parameters | Requirements |
General Requirements | ||
1 | Charger Capacity | 30KW |
2 | Model No. | ENC-DCX030A |
Input Requirements | ||
3 | AC Supply System | Three-Phase, 5 Wire AC system |
4 | Nominal Input voltage | AC380V±15% |
5 | Input frequency | 45-65Hz |
Environmental Requirements | ||
6 | Ambient Temperature Range | -25 to 55°C |
7 | Ambient Humidity | 5 to 95% |
8 | Storage temperature | -40 to 70°C |
Mechanical Requirements | ||
9 | IP Ratings | IP 54 |
10 | Cooling | Air-cooled |
Output Requirements | ||
11 | Number of outputs | 1 |
12 | Type of each output | DC200-750V |
13 | Output Current | Max.80 Amp |
14 | Output Connector Compatibility | IEC 62196 2017, IEC 61851 2017, SAE J1772, etc. |
15 | Power Factor | ≥0.99(50% load above) |
User Interface & Display Requirements | ||
16 | Display | 4.3 Inches Touch Screen with Shell |
17 | User Authentication | QR Code/ Password(Optional) |
18 | Metering Information | Consumption Units |
Communication Requirements | ||
19 | Communication between EVSE and Central Server | OCPP 1.6J Protocol (Optional) |
20 | Metering | Grid Responsive Metering as Per Units' Consumption of Each Vehicle |
21 | Interface between charger and CMS | Ethernet/3G/4G/WIFI (Optional) |
Protection & Safety Requirements | ||
22 | Safety Parameters | Over Current, Under Voltage, Residual Current, Surge Protection, Leakage Protection, Short Circuit, Over Temperature, etc. |